Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.203
Filtrar
1.
ANZ J Surg ; 94(4): 724-732, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38572937

RESUMO

INTRODUCTION: Surgical glove perforation has been linked to a double-fold increased risk of surgical site infection. Infection in the context of arthroplasty can have devastating consequences. In orthopaedics, use of polymethyl methacrylate (PMMA) bone cement is commonplace, and the impact on glove strength and perforation risk is not fully understood. This study aimed to examine the resistance to perforation and thickness of gloves following PMMA exposure, in accordance with the International Organization for Standardization (ISO) standard for glove integrity. METHODS: Pairs of gloves were separated and randomly sorted into exposure and control groups. Twenty pairs of latex and 40 pairs of polyisoprene gloves were used. Exposure group glove cuffs were in contact with cement from a single surface of the glove for 13 min as cement cured. Force to perforation and glove thickness were tested in accordance with ISO guidelines. RESULTS: Latex gloves were found to have a significantly increased force to perforation following PMMA exposure (10.26 Newtons (N) vs. 9.81 N, P = 0.048). Both polyisoprene under- and over-gloves were shown to have no significant change in strength to perforation post exposure (9.69 N vs. 9.83 N, P = 0.561, and 10.26 N vs. 10.65 N, P = 0.168, respectively). All groups were over the ISO standard minimum strength of 5 N. CONCLUSIONS: Exposure of latex and polyisoprene surgical gloves to PMMA bone cement does not appear to increase glove perforation risk and rather may improve natural rubber latex glove strength. This study supports the use of latex and polyisoprene surgical gloves in procedures that involve the handling of PMMA bone cement.


Assuntos
Luvas Cirúrgicas , Ortopedia , Humanos , Polimetil Metacrilato/efeitos adversos , Cimentos Ósseos/efeitos adversos , Látex
2.
Cureus ; 16(3): e55425, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38567238

RESUMO

Careful consideration of material properties used to construct denture base material in removable partial dentures (RPDs) is required for a successful outcome. Because of nylon's flexible nature, nylon denture bases are a widely used alternative material to polymethyl methacrylate (PMMA) in RPDs. Flexible dentures help with retention by creating a seal around the denture's border. In this study, we review current evidence on flexible dentures and provide an overview of their uses, advantages, and disadvantages. We conducted electronic research of English-language articles written between 2018 and 2023 that addressed the different physical and mechanical properties of flexible dentures. Flexible dentures' water sorption did not exceed ISO standards. Other physical properties we investigated, such as color stability and polymerization shrinkage, were lower in flexible dentures than in PMMA. Mechanical properties showed a lower value compared to PMMA, such as surface roughness and hardness, and impact strength. However, flexural strength was controversial. Retention was better in PMMA compared to flexible dentures. Finally, the retention of acrylic teeth compared to flexible dentures was better with the provision of extra mechanical retention means. Therefore, it is important to examine flexible dentures' properties, indications, advantages, and disadvantages when offering patients this solution.

3.
Ultrasound Med Biol ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38575416

RESUMO

OBJECTIVE: We have studied the use of polymethyl methacrylate (PMMA) as an alternative biopsy marker that is readily detectable with ultrasound Doppler twinkling in cases of in vitro, ex vivo, or limited duration in vivo settings. This study investigates the long-term safety and ultrasound Doppler twinkling detectability of a PMMA breast biopsy marker following local perturbations and different dwell times in a 6-mo animal experiment. METHODS: This study, which was approved by our Institutional Animal Care and Use Committee, involved three pigs and utilized various markers, including PMMA (Zimmer Biomet), 3D-printed, and Tumark Q markers. Markers were implanted at different times for each pig. Mesh material or ethanol was used to induce a local inflammatory reaction near certain markers. A semiquantitative twinkling score assessed twinkling for actionable localization during monthly ultrasounds. At the primary endpoint, ultrasound-guided localization of lymph nodes with detectable markers was performed. Following surgical resection of the localized nodes, histomorphometric analysis was conducted to evaluate for tissue ingrowth and the formation of a tissue rind around the markers. RESULTS: No adverse events occurred. Twinkling scores of all markers for all three pigs decreased gradually over time. The Q marker exhibited the highest mean twinkling score followed by the PMMA marker, PMMA with mesh, and Q with ethanol. The 3D-printed marker with mesh and PMMA with ethanol had the lowest scores. All wire-localized lymph nodes were successfully resected. Despite varying percentages of tissue rind around the markers and a significant reduction in overall twinkling (p < 0.001) over time, mean PMMA twinkling scores remained clinically actionable at 6 and 5 mo using a General Electric C1-6 probe and 9L-probe, respectively. CONCLUSIONS: In this porcine model, the PMMA marker demonstrates an acceptable safety profile. Clinically actionable twinkling aids PMMA marker detection even after 6 mo of dwell time in porcine lymph nodes. The Q marker maintained the greatest twinkling over time compared to all the other markers studied.

4.
J Vet Sci ; 25(2): e25, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38568826

RESUMO

BACKGROUND: Surgical excision is the treatment of choice for feline intracranial meningioma. OBJECTIVES: To report clinical findings, complications, and outcomes following surgery for feline intracranial meningioma. METHODS: Medical records (01/2000-01/2017) of cats that underwent surgical excision of an intracranial meningioma at our institution were reviewed. Patient data included signalment, clinical signs, surgical technique, complications, histopathologic diagnosis, survival time, and owners' answers to a satisfaction questionnaire. Survival was assessed using the Kaplan-Meier method and log-rank test. RESULTS: Twenty-six cats were included in this study. The exact cause of death was known in 17 cases and was not related to meningioma in 9/17 cases. Overall median survival time was 881 days (95% confidence interval 518; 1248). The age of the cat did not influence survival (p = 0.94) or the occurrence of complications (p = 0.051). Complications occurred in 13/24 cats, including dramatic complications in 4/24 cats. Most complications appeared in the first 24 hours post-surgery (12/13). Males had more postoperative complications (p = 0.042), including more seizures (p = 0.016). Cats with cranioplasty had fewer complications (p = 0.021). Clinical recurrence was confirmed in 3 out of 17 cats. Recurrence-free survival time was 826 days. Most owners (12/14) were satisfied with the outcome. CONCLUSIONS: Surgical treatment of intracranial meningioma in cats was associated with a long median survival time but also with a high rate of minor and major postoperative complications, including early postoperative seizures. Cranioplasty may reduce complications. Age at the time of surgery had no effect on outcomes.


Assuntos
Doenças do Gato , Neoplasias Meníngeas , Meningioma , Masculino , Gatos , Animais , Meningioma/cirurgia , Meningioma/veterinária , Estudos Retrospectivos , Complicações Pós-Operatórias/veterinária , Complicações Pós-Operatórias/epidemiologia , Neoplasias Meníngeas/cirurgia , Neoplasias Meníngeas/veterinária , Convulsões/veterinária , Resultado do Tratamento , Doenças do Gato/cirurgia
5.
Magn Reson Chem ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558418

RESUMO

Configurational and conformational analysis of the biologically relevant natural product artemisinin was conducted using carbon-carbon residual dipolar couplings (1DCC RDCs) at natural abundance. These RDCs were measured through the 2D-INADEQUATE NMR experiment using a sample aligned in a compressed poly (methyl methacrylate) (PMMA) gel swollen in CDCl3. Singular value decomposition (SVD) fitting analysis of all carbon-carbon bonds, 1DCC RDCs, in relation to the full configuration/conformational space (32 diastereoisomers) of artemisinin, unambiguously identified the correct configuration of artemisinin.

6.
J Dent ; : 104993, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38657724

RESUMO

OBJECTIVES: This study aimed to compare the physical and mechanical properties of four denture base materials: Polyan IC (PA), milled polymethylmethacrylate (PMMA), three-dimensional (3D)-printed resin (3DP), and SR Ivocap (SR). METHODS: Ninety-six samples were prepared and divided into four groups as follows. Group A consisted of 3DP (Asiga DentaBASE, Asiga) fabricated using a manufacturer-recommended 3D printer (Asiga Pro 4k, Asiga). Group B comprised milled PMMA (MP) (Ivotion Base, Ivoclar Vivadent). Group C included PA (BredentSenden), meanwhile, group D involved SR (Ivoclar VivadentSchaan). Cuboid samples (65 mm x 10 mm x 2.5 mm) were used for biaxial flexure strength testing in a universal testing machine (UTM). Cylindrical samples of 20 mm x 40 mm were used for compressive strength testing in a UTM. Additionally, cuboid samples (65 mm x 10 mm x 2.5 mm) were used for Vickers surface hardness testing in a microhardness tester. Disc samples (10 mm x 2.5 mm) were employed for color stability testing both in a coffee solution and Coca-Cola, using a digital spectrophotometer. Statistical analyses were performed using one-way analysis of variance and Tukey's post hoc analysis (α=.05). RESULTS: MP demonstrated superior compressive strength (p=0.002) and color stability compared to that exhibited by 3DP (p<0.001) while displaying similar flexure strength (p=0.336) and hardness (p=0.708). MP and PA displayed similar compressive strength (p=0.081), flexure strength (p=0.159), and color stability in coke (p=0.071). However, MP had reduced hardness (p<0.001) and color stability in coffee (p<0.001). Moreover, MP demonstrated a higher compressive strength (p<0.001) than that displayed by SR. However, the flexure strength, hardness, and color stability were similar (p > 0.05). Furthermore, 3DP exhibited comparable compressive strength (p=0.334) to that of PA but demonstrated significantly lower flexure strength (p=0.005), hardness (p<0.001), and color stability (p<0.001) compared to PA. In comparison to SR, PA had a higher compressive strength (p <0.001), hardness (p=0.001), and color stability in coffee (p<0.001), although they demonstrated similar (p>0.05) flexure strength and color stability in coke. CONCLUSIONS: The MP and PA demonstrated superior compressive strength than that exhibited by the other materials tested. The tested materials had similar flexure strengths, except for PA which demonstrated superiority over the 3DP. Among all tested materials, PA exhibited the highest hardness, while the 3DP was the least color-stable. CLINICAL SIGNIFICANCE: Considering the mechanical properties and color stability, Polyan and milled polymethylmethacrylate are preferred for complete denture fabrication. However, the limited repairability and complex handling of Polyan should be considered.

7.
J Proteome Res ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634750

RESUMO

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a widely employed technique in proteomics research for studying the proteome biology of various clinical samples. Hard tissues, such as bone and teeth, are routinely preserved using synthetic poly(methyl methacrylate) (PMMA) embedding resins that enable histological, immunohistochemical, and morphological examination. However, the suitability of PMMA-embedded hard tissues for large-scale proteomic analysis remained unexplored. This study is the first to report on the feasibility of PMMA-embedded bone samples for LC-MS/MS analysis. Conventional workflows yielded merely limited coverage of the bone proteome. Using advanced strategies of prefractionation by high-pH reversed-phase liquid chromatography in combination with isobaric tandem mass tag labeling resulted in proteome coverage exceeding 1000 protein identifications. The quantitative comparison with cryopreserved samples revealed that each sample preparation workflow had a distinct impact on the proteomic profile. However, workflow replicates exhibited a high reproducibility for PMMA-embedded samples. Our findings further demonstrate that decalcification prior to protein extraction, along with the analysis of solubilization fractions, is not preferred for PMMA-embedded bone. The biological applicability of the proposed workflow was demonstrated using samples of human PMMA-embedded alveolar bone and the iliac crest, which revealed anatomical site-specific proteomic profiles. Overall, these results establish a crucial foundation for large-scale proteomics studies contributing to our knowledge of bone biology.

8.
Sensors (Basel) ; 24(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38610321

RESUMO

The sensitivity and accuracy of nanopore sensors are severely hindered by the high noise associated with solid-state nanopores. To mitigate this issue, the deposition of organic polymer materials onto silicon nitride (SiNx) membranes has been effective in obtaining low-noise measurements. Nonetheless, the fabrication of nanopores sub-10 nm on thin polymer membranes remains a significant challenge. This work proposes a method for fabricating nanopores on polymethyl methacrylate (PMMA) membrane by the local high electrical field controlled breakdown, exploring the impact of voltage and current on the breakdown of PMMA membranes and discussing the mechanism underlying the breakdown voltage and current during the formation of nanopores. By improving the electric field application method, transient high electric fields that are one-seven times higher than the breakdown electric field can be utilized to fabricate nanopores. A comparative analysis was performed on the current noise levels of nanopores in PMMA-SiNx composite membranes and SiNx nanopores with a 5 nm diameter. The results demonstrated that the fast fabrication of nanopores on PMMA-SiNx membranes exhibited reduced current noise compared to SiNx nanopores. This finding provides evidence supporting the feasibility of utilizing this technology for efficiently fabricating low-noise nanopores on polymer composite membranes.

9.
Cureus ; 16(3): e55804, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38586635

RESUMO

STATEMENT OF PROBLEM: New-generation denture base materials are used successfully in denture fabrication; however, the effect of saliva pH change on the color stability of materials is unknown. PURPOSE: The purpose of this in vitro study is to evaluate the color stability of new-generation denture base materials after immersion in artificial saliva with different pH values (3,7,14). MATERIAL AND METHODS: Disc-shaped samples (Ø 10 mm x 2 mm) were prepared from three different denture base materials (1 pre-polymerized polymethylmethacrylate [PMMA], 1 graphene-reinforced PMMA, and heat-cure polymethyl methacrylate resin) (n=10). After polishing, color coordinates were measured using a PCE-CSM 5 colorimeter programmed in the CIE system (L* a* b*). The samples were kept in artificial saliva at different pH values and 37°C for 21 days. At the end of 21 days, color coordinates were measured again. The suitability of the measurements for a normal distribution was examined with the Kolmogro-Smirnov test. Whether color measurements obtained at different pH levels differed according to groups was examined with the Kruskal-Wallis test. The correlation between the CIEDE2000 and CIELab color difference formulas was examined by correlation analysis. RESULTS: The highest color difference occurred in heat-cure samples at pH 3 (p<0.001). The color difference at different pH values was least observed in pre-polymerized PMMA samples. Significant color differences occurred in the graphene-reinforced pre-polymerized PMMA group at pH 7 (p<0.001). CONCLUSIONS: It was observed that color differences occurred in all groups. Dentures made of new-generation CAD/CAM PMMA, which are less exposed to color differences, can be recommended for elderly patients with systemic diseases who are frequently exposed to pH changes in the oral cavity. CLINICAL IMPLICATIONS: Color differences on denture surfaces over time negatively affect aesthetics. Since pH changes cause changes on the prosthesis surface, it may be recommended for these patients to fabricate dentures from new-generation CAD/CAM PMMA resins, which are less deformable.

10.
J Pharm Bioallied Sci ; 16(Suppl 1): S918-S920, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595350

RESUMO

Objectives: This study compares the bacterial susceptibility to three different provisional restorations manufactured with different laboratory techniques, i.e., heat cure, CAD/CAM, and 3D printing. Materials and Methods: Totally, 45 health patients with age group of 30-60 years undergoing complete veneer crown treatment were selected for the study and divided into three groups with 15 samples in each as Group I: the crowns were made from polymethyl methacrylate polymer fabricated by the conventional heat cure method, Group 2: the crowns were made from polymethyl methacrylate fabricated by subtractive manufacturing CAD/CAM method, and Group 3: the crowns were made from oligomers fabricated by additive manufacturing 3D printing. The samples were examined for bacterial adherence at scanning electron microscope. The colony-forming units (CFUs) were calculated, and statistically analyzed. Results: It has been determined that the digitally fabricated provisional restorations prove to be superior in terms of surface topography than to the conventionally fabricated provisional restorations. Conclusion: The study concludes that 3D-printed provisional restorations are more precise with reduced bacterial susceptibility than milled ones.

11.
J Pharm Bioallied Sci ; 16(Suppl 1): S484-S487, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595441

RESUMO

Introduction: Dentures aim to replicate natural dentition's esthetics and functions as much as possible. With computer-aided design/computer-aided manufacturing (CAD/CAM) technology, dentistry had a new renaissance with workflow and materials. Aim: The aim is to compare the fracture toughness of the milled, 3D-printed, and conventional polymethyl methacrylate (PMMA) to those processed conventionally. Materials and Methods: 10 CAD MILLED PMMA BLOCKS, 10 3D PRINTED PMMA BLOCKS, and 10 CONVENTIONAL (HEAT CURE) PMMA BLOCKS. Results: A significant difference was seen in the mean flexural module when compared among three study groups as P < 0.05. It was found to be maximum in CAD/CAM PMMA, followed by conventional heat cure and 3D-printed PMMA. Conclusion: Formlabs and Dentca (3D-printed) were significantly weaker in fracture toughness compared to Leucitone 199 (conventional) (P < 0.05). Leucitone 199 (conventional) was significantly weaker in fracture toughness compared to Avadent (CAD CAM) (P < 0.05).

12.
J Prosthodont ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38483093

RESUMO

PURPOSE: The purpose of this study was to evaluate the flexural strength (FS), flexural modulus (FM), and fatigue limit (FL) of 3D-printed resin-based polymers and composites and compare them to 3D-printed composites. MATERIALS AND METHODS: A bar-shaped specimen (25 × 2 × 2 mm) was CAD designed according to ISO 4049:2019, and 60 duplicates of the 3D model were nested at a 45-degree angle with the printing platform and 3D-printed with three materials: denture teeth resin (Denture Teeth, Formlabs), temporary crown and bridge resin (Temporary CB, Formlabs), and composite (Flexcera Smile Ultra+, Desktop Health). The 3D model was also imported into a dental CAM software, duplicated 60 times, nested, and milled from a 3D-milled composite puck (Ivotion Denture Teeth, Ivoclar). All specimens were post-processed following the manufacturer's recommendation. The specimens were then subjected to a three-point bending test until failure using a Universal Testing Machine at a crosshead speed of 0.75 mm/min, and FS and FM were calculated. The remaining thirty specimens were tested for Fatigue Limit using the staircase approach starting at 50% FS maximum up to 1.2 M cycles at 10 Hz. The data were analyzed using one-way ANOVA and the Weibull distribution (α = 0.05). RESULTS: The results showed that Ivotion and Flexcera had higher FS (110.3 ± 7.1 MPa and 107.6 ± 6.4 MPa, respectively) and FM (3.3 ± 0.1 GPa and 3.0 ± 0.2 GPa, respectively) compared to the 3D-printed Denture Teeth (FS = 66.4 ± 18.5 MPa and FM = 1.8 ± 0.1 GPa) and Temporary CB (FS = 79.6 ± 12.1 MPa and FM = 2.7 ± 0.4 GPa). Weibull analysis showed that the Ivotion and Flexcera had a more uniform and narrower spatial distribution of defects (m: 27.98 and 29.19) than the printed materials, which had m values of 8.17 and 4.11 for Temporary CB and Denture Teeth, respectively. Although no differences were found in the static properties (FS and FM) between Ivotion and Flexcera, Ivotion presented a higher endurance limit than Flexcera (51.43 vs. 40.95 MPa). The Temporary CB presented 21.08 MPa and Denture Teeth presented 17.80 MPa of endurance limit. CONCLUSIONS: 3D-milled (Ivotion Denture Teeth) and 3D-printed (Flexcera Smile Ultra+) composites outperformed 3D-printed resins (Formlabs Denture Teeth and Temporary Crown & Bridge) in terms of flexural properties and fatigue resistance. 3D-milled (Ivotion) and 3D-printed (Flexcera) composites exhibited similar flexural properties, but 3D-milled composites showed a 25% higher fatigue endurance limit, suggesting improved clinical longevity.

13.
R Soc Open Sci ; 11(3): 231694, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38545617

RESUMO

Bone cement is one of the materials used in orthopaedics that serves various functions, such as binding bone implants, replacing damaged bones and filling spaces within bones. Various materials have been used to synthesize bone cement, and one promising material for further research is fish bone waste-based bone cement. This study investigates the potential of fish bone waste-based bone cement by incorporating nano fish bone (NFB) and L-arginine (L-Arg) protein into polymethyl methacrylate (PMMA) to examine apatite growth. NFB derived from the Salmo salar fish positively influences osteoblast cell proliferation and differentiation, while L-Arg enhances biocompatibility and antibiotic properties. The NFB/L-Arg combination holds promise in accelerating new bone formation and cell growth, both of which are crucial for fracture healing and bone remodelling. Tensile strength tests reveal the superior performance of BC-PMMA-1-NFB/L-Arg (36.11 MPa) compared with commercial PMMA (32 MPa). Immersion tests with simulated body fluid (SBF) solution for 7 days reveal accelerated apatite layer formation, emphasizing the potential benefits of NFB/L-Arg in bone cement applications.

14.
ACS Biomater Sci Eng ; 10(4): 2151-2164, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38453640

RESUMO

Poly(methyl methacrylate) (PMMA) is commonly used for dental dentures, but it has the drawback of promoting oral health risks due to oral bacterial adhesion. Recently, various nanoparticles have been incorporated into PMMA to tackle these issues. This study aims to investigate the mechanophysical and antimicrobial adhesive properties of a denture resin by incorporating of nanoclay into PMMA. Specimens were prepared by adding 0, 1, 2, and 4 wt % surface-modified nanoclay (Sigma) to self-polymerizing PMMA denture resin. These specimens were then evaluated using FTIR, TGA/DTG, and FE-SEM with EDS. Various mechanical and surface physical properties, including nanoindentation, were measured and compared with those of pure PMMA. Antiadhesion experiments were conducted by applying a Candida albicans (ATCC 11006) suspension to the surface of the specimens. The antiadhesion activity of C. albicans was confirmed through a yeast-wall component (mannan) and mRNA-seq analysis. The bulk mechanical properties of nanoclay-PMMA composites were decreased compared to those of pure PMMA, while the flexural strength and modulus met the ISO 20795-1 requirement. However, there were no significant differences in the nanoindentation hardness and elastic modulus. The surface energy revealed a significant decrease at 4 wt % nanoclay-PMMA. The antiadhesion effect of Candida albicans was evident along with nanoclay content in the nanocomposites and confirmed by the reduced attachment of mannan on nanoclay-PMMA composites. mRNA-seq analysis supported overall transcriptome changes in altering attachment and metabolism behaviors on the surface. The nanoclay-PMMA materials showed a lower surface energy as the content increased, leading to an antiadhesion effect against Candida albicans. These findings indicate that incorporating nanoclay into PMMA surfaces could be a valuable strategy for preventing the fungal biofilm formation of denture base materials.


Assuntos
Adesivos , Polimetil Metacrilato , Mananas , Teste de Materiais , Dentaduras , RNA Mensageiro
15.
Materials (Basel) ; 17(6)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38541551

RESUMO

Powder injection molding is an established, cost effective and often near-net-shape mass production process for metal or ceramic parts with complex geometries. This paper deals with the extension of the powder injection molding process chain towards the usage of a commercially available borosilicate glass and the realization of glass compounds with huge densities. The whole process chain consists of the individual steps of compounding, molding, debinding, and sintering. The first part, namely, the search for a suitable feedstock composition with a very high solid load and reliable molding properties, is mandatory for the successful manufacture of a dense glass part. The most prominent feature is the binder composition and the related comprehensive rheological characterization. In this work, a binder system consisting of polyethylene glycol and polymethylmethacrylate with stearic acid as a surfactant was selected and its suitability for glass injection molding was evaluated. The influence of all feedstock components on processing and of the process steps on the final sintered part was investigated for sintered glass parts with densities around 99% of the theoretical value.

16.
Polymers (Basel) ; 16(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38543426

RESUMO

The polarization state of light waves significantly affects the quality of holographic recordings. This paper quantitatively analyzes the impact of different polarization states of signal and reference beams on the quality of holographic recordings in PQ/PMMA photopolymer systems during the holography process. By deriving the light field distribution of the interference between two light waves of different polarization states and introducing the interference fringe contrast and the modulation of the refractive index of the photopolymer, we established the relationship between the diffraction efficiency of PQ/PMMA photopolymer holographic gratings and the angle between polarization directions. Based on this relationship, simulations and experiments were conducted. The experimental results demonstrated that as the angle between the polarization directions increased, the diffraction efficiency of the material decreased, with the efficiency dropping to 24.69% of its original value when the angle increased from 0° to 50°. When the angle increased to 60°, the influence of polarization characteristics became gradually significant, and at 90°, it was entirely dominated by polarization characteristics. The photoinduced birefringence properties of the PQ/PMMA prepared in the measurement experiment were studied, and the polarization characteristics of the reconstructed light under polarization direction angles of 0°, 60°, and 90° were investigated. The results indicated that at a polarization direction angle of 60 degrees, the material exhibited a significant response to the polarization information of the signal light. Finally, holographic recordings of objects at different polarization direction angles were conducted, and the reconstructed images were used to visually reflect the impact of the polarization direction angle on the quality of holographic recordings.

17.
Artigo em Inglês | MEDLINE | ID: mdl-38521483

RESUMO

BACKGROUND: Locking plates are widely used in open reduction internal fixation (ORIF) for proximal humeral fracture (PHF). However, the optimal surgical treatment of unstable, displaced PHF in elderly patients remains controversial. This study aimed to compare the radiological and clinical outcomes of surgical treatment of PHF in the elderly with locking plate (LP) alone and locking plate combined with 3D printed polymethylmethacrylate (PMMA) prosthesis augmentation (LP-PA). METHODS: From May 2015 to April 2021, a total of 97 patients aged ≥ 60 years with acute unstable PHF who underwent osteosynthesis with either LP (46 patients) or LP-PA (51 patients) were retrospectively analyzed. For the LP-PA group, a customized proximal humeral prosthesis made of PMMA cement was intra-operatively fabricated by a three-dimensional (3D) printed prototype mold for the humeral medial support. Radiological outcomes were analyzed by measuring the value of neck-shaft angle (NSA) and humeral head height (HHH). The clinical outcomes were evaluated using Constant-Murley Score (CMS), Disabilities of the Arm Shoulder and Hand (DASH) score, American Shoulder and Elbow Surgeons (ASES) score, and the shoulder range of motion (ROM). Pain was measured using a visual analogue scale (VAS). RESULTS: At the one-year follow-up, all fractures healed radiologically and clinically. The mean changes of NSA and HHH over the follow-up period were markedly smaller in the LP-PA group (3.8 ± 0.9° and 1.7 ± 0.3 mm) than those in the LP group (9.7 ± 2.1° and 3.2 ± 0.6 mm, both P < 0.0001). The LP-PA group also presented lower DASH score (17.1 ± 3.6), higher ASES score (89.5 ± 11.2) and better ROM in forward elevation (142 ± 26°) and external rotation (59 ± 11°) compared to the LP group (28.9 ± 4.8 for DASH score, P < 0.0001; 82.3 ± 9.0 for ASES score, P < 0.001; 129 ± 21° for forward elevation, P = 0.008; and 52 ± 9° for external rotation, P = 0.001). There was no significant difference in overall complication rate between the two groups, although the complication rate of screw perforation was higher in the LP-PA group (P = 0.172). CONCLUSIONS: For PHF in elderly patients, the combination of LP fixation and PMMA prosthesis augmentation effectively improved humeral head support and reduction maintenance, providing satisfactory outcomes both radiologically and clinically. This technique also reduced the incidence of screw perforation associated with plate fixation alone, making it a reasonable option to ensure satisfactory clinical outcomes.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38536823

RESUMO

INTRODUCTION: The increase in infectious diseases mediated by oral bacteria has been one of the most potent threats to human health, specifically to the elderly. Researchers seek to incorporate antimicrobial nanomaterials into PMMA to control the colonization of microorganisms and reduce deadly diseases. OBJECTIVE: To conduct a systematic review to answer the question: "Does graphene oxide incorporated into polymethylmethacrylate influence its antimicrobial activity?" METHODS: The electronic search was performed in PubMed, Embase, Web of Science, Scopus, and Google Scholar databases, and articles published until October 2021 were selected. The search terms were: ("acrylic resin" OR PMMA) AND (graphene OR "oxide graphene") AND (antimicrobial OR antibacterial OR "anti-infective agent"). The risk of bias analysis of the articles was performed using the quasi-experimental study assessment tool adapted from the JBI. RESULTS: Two hundred and fifty-nine articles were found in the databases. After removing the duplicates, 245 were analyzed by title and abstract. Of these, 06 were selected for full reading, of which 03 met the eligibility criteria and were included in this systematic review. CONCLUSION: This systematic review's findings can infer that the incorporation of graphene in the form of graphene-based coatings to PMMA showed antimicrobial effectiveness.

19.
Materials (Basel) ; 17(5)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38473585

RESUMO

One therapeutical alternative in the treatment of functional disorders is the use of printed oral splints. The mechanical properties of these materials are highly essential to their clinical effectiveness, and their performance may vary depending on factors such as cleaning, post-polymerization, or their orientation during construction. The objective of this in vitro investigation is to evaluate the effectiveness of the selected materials in terms of their biaxial flexural strength in relation to the criteria listed above. Splint materials were used in the printing of 720 discs. The printing process was carried out in different orientations in relation to the building platform. Either an automatic or manual cleaning process was performed on the samples. For post-polymerization, either an LED or Xenon light was utilized. A piston-on-three-ball test was used to measure the biaxial flexural strength (BFS) of the materials after they were stored in water for either 24 h or 60 days. The homogeneity of the data was controlled by employing the Levene method, and the differences between the groups were analyzed using the ANOVA and Bonferroni methods. After being stored for twenty-four hours, the mean BFS ranged anywhere from 79 MPa to 157 MPa. Following a period of sixty hours, the BFS exhibited a substantial drop and revealed values that ranged from 72 to 127 MPa. There was no significant difference that could be identified between the materials or between the various cleaning processes. The results of post-polymerization showed that the LED light produced higher means than the Xenon light did. In terms of position, the mean values varied greatly, with 0°'s mean value being 101 MPa, 45°'s mean value being 102 MPa, and 90°'s mean value being 115 MPa. The use of a build orientation of 90° and post-polymerization with LED light resulted in significantly increased biaxial flexural strength. According to this study, this design should be implemented in order to ensure that splint materials have the highest possible strength.

20.
Foot Ankle Int ; : 10711007241237804, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501724

RESUMO

BACKGROUND: Even with the best conservative care, patients with Charcot neuroarthropathy (CN) of the foot and ankle often ulcerate, increasing their risk of infection, amputation, and death. Surgical fixation has been associated with risk of recurrent ulceration, potentially due to poor bone quality prone to recurrent deformity and ulceration. We propose midfoot beam reconstruction with PMMA augmentation as a novel means of improving fixation. METHODS: A protocol was developed to create characteristic CN midfoot fragmentation both visually and fluoroscopically in each of 12 matched-pair cadaveric feet. Afterward, the pairs were divided into 2 groups: (1) midfoot beam fusion surgery alone, and (2) midfoot beam fusion surgery augmented with PMMA. A solid 7.0-mm beam was placed into the medial column and a solid 5.5-mm beam was placed across the lateral column. In the PMMA group, 8 to 10 mL of PMMA was inserted into the medial column. The hindfoot of each specimen was potted and the metatarsal heads were cyclically loaded for 1800 cycles, followed by load to failure while load and displacement were continually recorded. RESULTS: One specimen in the beam alone group failed before reaching the 1800th cycle and was not included in the failure analysis. The midfoot beam only group demonstrated greater mean displacement during cycle testing compared with the PMMA group, P < .05. The maximum force (N), stiffness (N/mm), and toughness (Nmm) were all significantly greater in the group augmented with PMMA, P < .05. CONCLUSION: In a CN cadaveric model, PMMA augmentation significantly decreased gapping during cyclic loading and nearly doubled the load to failure compared with midfoot beams alone. CLINICAL RELEVANCE: The results of this biomechanical study demonstrate that augmentation of midfoot beams with PMMA increases the strength and stiffness of the fusion construct. This increased mechanical toughness may help reduce the risk of nonunion and infection in patients with neuropathic midfoot collapse.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...